Product Description
NoBurn fire cable is manufactured in the UK using the latest technology, materials and manufacturing equipment. Our materials and production processes are audited by LPCB and BASEC to ensure consistent reliability and quality, with each reel fully traceable by batch number and time and date of manufacture.
NoBurn is the fastest fire cable to prepare for termination with no troublesome multiple sheaths, foils or wraps to strip, NoBurn cable has superb working flexibility and stays where you put it, reducing installation time and costs.
Approved by LPCB and BASEC to meet with BS 5839-1:2002+A2:2008 Clause 26.2d Standard, BS EN 50200:2006 + Annex E 30 minutes & BS EN 50200:2006 Class PH120, NoBurn's core twists will provide the highest level of data protection, ideal for long cable runs and analogue addressable fire systems. Also certified by LPCB and BASEC to BS 7629-1:2008 & BS 6387:1994 Clause 11 CWZ including 3 hour burn test at 950°c.
NoBurn Platinum fire cable is also the most highly certified cable for use with Emergency Lighting Systems, certified to exceed BS 5266-1 2005's EN 50200 PH60 - 1 hour duration, NoBurn Platinum is certified by LPCB and BASEC to withstand to PH120 - providing 2 hours of protection. Also suitable for automatic lift doors, air conditioning and computer control where low smoke, fume and zero halogen cable is required.
Features
- Fastest Standard Fire Cable to Prepare for Termination
- Easy to Install and Superb Working Flexibility
- Twisted Cores to Provide High Level Data Protection
- Full Size CPC (Earth Core)
- Red, White & Black Outer Sheaths Available
- 1mm²,1.5mm², 2.5mm² & 4.0mm²
- 500 Metre and Special Lengths Available
- Aluminium / Co-polymer Foil Screen
Approved and Certified to meet
- BS 5839-1:2002 +A2:2008 Clause 26.2d - 'Standard' Fire Cable
- BS EN 50200:2006 + Annex E 30 Minutes - Fire Resistance Standard
- BS EN 50200:2006 PH120 - Fire Resistance Standard
- BS 7629-1:2008 - Fire Resistance Standard
- BS 6387:1994 Clause 11 CWZ - Fire Resistance Standard
- BS EN 50267-2-1:1999 - Halogen Emission Standard
- BS EN 61034-2:2005 - Low Smoke Standard
Also Approved For
- Emergency Lighting Standard - BS 5266-1:2005
- Voice Alarm Systems Standard - BS 5839-8:2008
- Voice Communication Standard - BS 5839-9:2003
Manufacturers Recommended Installation Guide Lines
Recommended metal clip spacing 300mm Horizontal, 400mm Vertical
Recommended Cable Tray Fastening - Metal Tie, spacing every 1.5 metres.
Installation Temperatures:
- Minimum installation Temperature 0ºc
- Maximum installation Temperature 70 C
Operating Temperature Temperature:
- Minimum -40 C to Maximum +90 C
The cable should not be flexed or bent when either the cable or operating temperature is below the recommended installation temperatures.
Minimum Bend Radius = 6 x Diameter
Plastic Clips or ties must not be used as the sole means of support for fire cable.
Ventcroft Standard Fire Performance Cable |
|||||||
|
Red |
Red 1mm Cores & CPC (earth) | Reel | Cores | Code | Pallet | Min Qty | Trade Per 100m |
|
|
1mm | 100m | 2 Cores & CPC |
VFP-210ERH |
60 | 1 | TBA |
| 1mm |
100m | 3 Cores & CPC |
VFP-310ERH |
60 | 1 | TBA | |
| 1mm | 100m | 4 Cores & CPC |
VFP-410ERH |
60 | 1 | TBA | |
| 1mm | 500m | 2 Cores & CPC |
VFP-210ERH500M |
10 | 1 | TBA | |
|
|
Red 1.5mm Cores & CPC (earth) | Reel | Cores |
Code |
Pallet | Min Qty | Trade Per 100m |
| 1.5mm | 100m | 2 Cores & CPC |
VFP-215ERH |
60 | 1 | TBA | |
| 1.5mm | 100m | 3 Cores & CPC |
VFP-315ERH |
60 | 1 | TBA | |
| 1.5mm | 100m | 4 Cores & CPC |
VFP-415ERH |
60 | 1 | TBA | |
| 1.5mm | 200m | 2 Cores & CPC |
VFP-215ERH200M |
20 | 1 | TBA | |
| 1.5mm | 200m | 4 Cores & CPC |
VFP-415ERH200M |
20 | 1 | TBA | |
| 1.5mm | 500m | 2 Cores & CPC |
VFP-215ERH500M |
10 | 1 | TBA | |
| 1.5mm | 500m | 4 Cores & CPC |
VFP-415ERH500M |
10 | 1 | TBA | |
| Red 2.5mm Cores & CPC (earth) | Reel | Cores |
Code |
Pallet | Min Qty | Trade Per 100m | |
| 2.5mm | 100m | 2 Cores & CPC |
VFP-225ERH |
60 | 1 | TBA | |
| 2.5mm | 100m | 3 Cores & CPC |
VFP-325ERH |
60 | 1 | TBA | |
| 2.5mm | 100m | 4 Cores & CPC |
VFP-425ERH |
60 | 1 | TBA | |
| 2.5mm | 200m | 2 Cores & CPC |
VFP-225ERH200M |
20 | 1 | TBA | |
| 2.5mm | 500m | 2 Cores & CPC |
VFP-225ERH500M |
10 | 1 | TBA | |
| Red 4mm Cores & CPC (earth) | Reel |
Cores |
Code |
Pallet | Min Qty | Trade Per 100m | |
| 4mm | 100m | 2 Cores & CPC |
VFP-S240ERH |
60 | 1 | TBA | |
Ventcroft Standard Performance Cable |
|||||||
|
White |
Red 1mm Cores & CPC (earth) | Reel | Cores | Code | Pallet | Min Qty | Trade Per 100m |
|
|
1mm | 100m | 2 Cores & CPC | VFP210EWH | 60 | 1 | TBA |
| 1mm | 100m | 3 Cores & CPC | VFP-310EWH | 60 | 1 | TBA | |
| 1mm | 100m | 4 Cores & CPC | VFP-410EWH | 60 | 1 | TBA | |
| 1mm | 500m | 2 Cores & CPC | VFP-210EWH500M | 10 | 1 | TBA | |
|
|
White 1.5mm Cores & CPC (earth) |
Reel | Cores | Code | Pallet | Min Qty | Trade Per 100m |
| 1.5mm | 100m | 2 Cores & CPC | VFP-215EWH | 60 | 1 | TBA | |
| 1.5mm | 100m | 3 Cores & CPC | VFP-315EWH | 60 | 1 | TBA | |
| 1.5mm | 100m | 4 Cores & CPC | VFP-415EWH | 60 | 1 | TBA | |
| 1.5mm | 200m | 2 Cores & CPC | VFP-215EWH200M | 20 | 1 | TBA | |
| 1.5mm | 200m | 4 Cores & CPC | VFP-415EWH200M | 20 | 1 | TBA | |
| 1.5mm | 500m | 2 Cores & CPC | VFP-215EWH500M | 10 | 1 | TBA | |
| 1.5mm | 500m | 4 Cores & CPC | VFP-415EWH500M | 10 | 1 | TBA | |
|
|
White 2.5mm Cores & CPC (earth) | Reel | Cores | Code | Pallet | Min Qty | Trade Per 100m |
| 2.5mm | 100m | 2 Cores & CPC | VFP-225EWH | 60 | 1 | TBA | |
| 2.5mm | 100m | 3 Cores & CPC | VFP-325EWH | 60 | 1 | TBA | |
| 2.5mm | 100m | 4 Cores & CPC | VFP-425EWH | 60 | 1 | TBA | |
| 2.5mm | 200m | 2 Cores & CPC | VFP-225EWH200M | 20 | 1 | TBA | |
| 2.5mm | 500m | 2 Cores & CPC | VFP-225EWH500M | 10 | 1 | TBA | |
|
|
White 4mm Cores & CPC (earth) | Reel | Cores | Code | Pallet | Min Qty | Trade Per 100m |
| 4mm | 100m | 2 Cores & CPC |
VFP-S240EWH |
60 | 1 | TBA | |
Ventcroft Standard Fire Performance Cable |
|||||||
| Black | Black | Reel | Cores | Code | Pallet | Min Qty | Trade Per 100m |
|
|
1.5mm | 100m | 2 Cores & CPC | VFP-215EBKH | 60 | 1 | TBA |
| 2.5mm | 100m | 2 Cores & CPC | VFP-225EBKH |
60 | 1 | TBA | |
| 1.5mm | 100m | 4 Cores & CPC | VFP-415EBKH | 60 | 1 | TBA | |
Fire Performance Cable Part Code Break Down |
|||||||
|
VFP-210ER |
|||||||
| VFP | - | 2 | 10 | E | R | H | |
| Product Type | Conductors | CSA | CPC Type | Outer Sheath Colour | Core Colours | Length | |
| Ventcroft Fire Performance Cable "NoBurn Platinum" |
2 - 2 Core
4 - 4 Core |
10 - 1.0mm
15 - 1.5mm 25 - 2.5mm |
E - CPC & Screen |
R - Red
W - White |
H- Harmonised Colours
- Old Colours |
- 100M